(1.Department of Electric Power Engineering,Xi’an Jiaotong University,Xi’an 710049,Shaanxi PRovince, China;2.Research Center for Aviation Engineering and Technology,Beijing 100076 China;3.Xi’an University of Architecture & Technology,Xi’an 710055,Shaanxi Province,China)
ABSTRACT:An effective method to detect, localize, identify, and classify power quality disturbance is proposed. Firstly, the signal containing noise is de-noised by wavelet transform to obtain a signal with higher signal-to-noise ratio. Then the de-noised signal is differentiated to form a difference signal and the duration and position of the disturbance can be determined. Using phase-shifting of the de-noised single phase signal by -60° to achieve a virtual symmetrical three phase voltage system and using the three phase voltages to substitute the three phase currents, the instantaneous active power can be calculated by means of instantaneous reactive power theory, and then the amplitude of instantaneous voltage can be calculated, therefore, the type of the disturbance can be identified by the duration and amplitude of the disturbance.
KEY WordS: Instantaneous reactive power theory;Wavelet de-noising;Classify and identification;Power quality disturbance;Power system
[1] Gaouda A M,Salama M M A,Sultan M R et al.Power quality detection and classification using wavelet-multiresolution signal decompositon[J].IEEE Trans on Power Delivery,1998,13(4):1469-1476.
[2] Gaouda A M,Salama M M A,Sultan M R et al.application of multiresolution signal decomposition for monitoring short-duration variations in distribution systems[J].IEEE Trans on Power Delivery,2000,15(2):478-485.
[3] Angrisani L,Daponte P,D’Apuzzo M et al.A measurement method based on the wavelet transform for power quality analysis[J].IEEE Trans on Power Delivery,1998,13(4):990-998.
[4] 胡铭, 陈珩(Hu Ming,Chen Heng).基于小波变换模极大值的电能质量扰动检测与定位(Detection and location of power quality disturbances using wavelet transform modulus maxima)[J].电网技术(Power System Technology),2001,25(3):12-16.
[5] Karimi M,Mokhtari H,Iravani R.Wavelet based on-line disturbance detection for power quality applications[J].IEEE Trans on Power Delivery,2000,15(4):1212-1220.
[6] 陈祥训(Chen Xiangxun).采用小波技术的几种电能质量扰动的测量与分类方法(Wavelet-based measurements and classification of short duration power quality disturbances)[J].中国电机工程学报(Proceedings of the CSEE),2002,22(10):1-6.
[7] Donoho D L.De-noising by soft-thresholding[J].IEEE Trans on Information Theory,1995,41(3):613-627.
[8] Peng F Z,Akagi H,Nabae A.Compensation characteristics of the combined system of shunt passive and series active filters[J].IEEE Trans on Industry Applications,1993,29(1):144-152.
[9] Fujita H,Akagi H.A practical approach to harmonic compensation in power systems——series connection of passive and active filters [J].IEEE Trans on Industry Applications,1991,27(6):1020-1025.
[10] IEC 61000-4-15,Testing and measurement techniques:flickermeter-functional and design specifications[S].